| Sign In | Join Free | My infospaceinc.com |
|
Sensor Type : Temperature Sensor
Description : Temperature Sensor Multifunction RoHS
Mfr. Part # : 101021013
Model Number : 101021013
The SEN5x is an advanced environmental sensor node designed for HVAC and air quality applications. It integrates multiple sensing capabilities, including particulate matter (PM), NOx, VOC, relative humidity (RH), and temperature (T). This platform offers fast and easy integration with a single driver for up to 8 data signals, superior sensing accuracy, and a long lifetime. The fully calibrated digital output simplifies implementation in various systems.
| Parameter | Conditions | Value | Units | Notes | |
| Sensor Module | Sampling interval | 1 0.03 | s | ||
| Lifetime (24h/day operation) | > 10 | years | Based on MTTF calculation. May vary with operating conditions. | ||
| Acoustic emission level (0.2 m) | 24 | dB(A) | |||
| Long term acoustic emission level drift (0.2 m) | +0.5 / year | dB(A) | |||
| Particulate Matter | Mass concentration specified range | 0 to 1000 | g/m | ||
| Mass concentration size range | PM1.0: 0.3 to 1.0 m, PM2.5: 0.3 to 2.5 m, PM4: 0.3 to 4.0 m, PM10: 0.3 to 10.0 m | m | |||
| Mass concentration precision (PM1, PM2.5) | 0 to 100 g/m | 5 g/m AND 5 % m.v. | |||
| Mass concentration precision (PM1, PM2.5) | 100 to 1000 g/m | 10 % m.v. | |||
| Mass concentration precision (PM4, PM10) | 0 to 100 g/m | 25 g/m | |||
| Mass concentration precision (PM4, PM10) | 100 to 1000 g/m | 25 % m.v. | |||
| Typical start-up time (number concentration) | 200 3000 #/cm | 8 | s | Time after starting Measurement-Mode until stable measurement. | |
| Temperature and Humidity | Typical accuracy temperature | @ 15-30 C, 50 %RH | 0.45 | C | |
| Max. accuracy temperature | @ 15-30 C, 50 %RH | 0.7 | C | ||
| Typical accuracy relative humidity | @ 25 C, 30-70 %RH | 4.5 | %RH | ||
| Max. accuracy relative humidity | @ 25 C, 30-70 %RH | 6 | %RH | ||
| Response time relative humidity | @ 25 C, 50 %RH, 63% | < 20 | s | ||
| Gas Sensing | Output signals | VOC Index | 1 500 | VOC Index points | |
| Output signals | NOx Index | 1 500 | NOx Index points | ||
| Device-to-device variation | VOC Index | <15 | VOC Index points or % VOC Index m.v. (the larger) | ||
| Device-to-device variation | NOx Index | <25 | NOx Index points or % NOx Index m.v. (the larger) | ||
| Repeatability | VOC Index | <5 | VOC Index points or % VOC Index m.v. (the larger) | ||
| Repeatability | NOx Index | <10 | NOx Index points or % NOx Index m.v. (the larger) | ||
| Operating Conditions | Temperature | Recommended: 10 to 40 C, Absolute Max/Min: -10 to 50 C | C | ||
| Relative humidity | Recommended: 20 to 80 %RH, Absolute Max/Min: 0 to 90 %RH (non-condensing) | % RH |
|
|
Particulate matter VOC humidity and temperature environmental sensor node Seeed 101021013 for air applications Images |