| Sign In | Join Free | My infospaceinc.com |
|
Description : Gas Sensor RoHS
Mfr. Part # : INIR-ME5%
Model Number : INIR-ME5%
Product Overview
The SGX Integrated IR (INIR) sensor is a user-friendly digital gas sensor utilizing the latest SGX Sensortech Infrared technology. Designed for reliability and ease of implementation, it incorporates a microcontroller with an ARM7 core and embedded software to process raw signals into linear, temperature-compensated outputs proportional to gas concentration. The INIR offers triple-range detection with linear approximation for Carbon Dioxide and Methane, automatic range switching, high resolution up to 10ppm, and multi-sensor mode capabilities. It provides both analog and serial port (UART) communication, with active and reference signals monitored, and full fault diagnostics. Designed for use in hazardous areas, the INIR is certified for explosive atmospheres (EX). Its compact design and factory calibration options significantly reduce development time and expertise required for integration into gas detection instruments.
| Specification | Min | Typical | Max | Notes |
|---|---|---|---|---|
| Absolute Maximum Ratings | ||||
| Supply Voltage | 3.2 VDC | 3.3 VDC | 5.25 VDC | |
| Average Current Consumption | 30mA | 32mA | 35 mA | *Inrush Current can be up to 65mA |
| Logic Outputs Level | ||||
| LOW Voltage Level (VOL) | 0.6V | Maximum 1.6mA source current | ||
| HIGH Voltage Level (VOH) | 2.0V | Minimum | ||
| Logic Inputs Level | ||||
| LOW Voltage Level (VINL) | 0.4V | Maximum | ||
| HIGH Voltage Level (VINH) | 2.0V | Minimum | ||
| Humidity | ||||
| Operating Humidity | 0% | 50% | 99% | Condensation may affect performance. Algorithms implemented to minimize effects. |
| Storage Humidity | 0% | 50% | 90% | |
| Temperature | ||||
| Operating Temperature | -40 C | +20 C | +75 C | |
| Storage Temperature | -20 C | +20 C | +55 C | |
| Temp. Cycle Limits | 0.8C/min | 1.3C/min | ||
| Pressure | ||||
| Operating Pressure | 80kPa | 120kPa | Compensation will be required. | |
| Storage Pressure | 80kPa | 120kPa | ||
| Performance | ||||
| DAC Resolution | 12-Bit at 0.0-2.5 Volts DC | Max Scalable according to Gas Conc. | ||
| Digital Signal Format | 8 data bits, 1 stop bit, no parity | |||
| Baud Rate | 38400 (default) | 115200, 19200, 9600 supported | ||
| Dimensions (mm) | ||||
| Diameter (D) | 19.9 | 20 | 20.1 | |
| Height (H) | 16.50 | 16.60 | 16.70 | |
| Pins Height (pH) | 4.0 | 4.8 | 5.6 | |
| Weight | 25 g | 29 g | 33 g | |
| Pin Configuration | ||||
| Pin 1 | TXD (Data transmitted from the Integrated IR) | |||
| Pin 2 | +VCC (3.2 Volts 5.25 Volts DC input) | |||
| Pin 3 | GND (0 Volts reference) | |||
| Pin 4 | RXD (Data received by the Integrated IR) | |||
| Pin 5 | OUT (Analog Output) | |||
| Models / Calibration | ||||
| Ordering Code | Methane Detection | Carbon Dioxide Detection | Standard Calibration | |
| INIR-ME100% | YES | NO | 0-100% | |
| INIR-ME5% | YES | NO | 0-5% | |
| INIR-CD5% | NO | YES | 0-5% | |
| INIR-EK4 | Evaluation Kit (without sensor) | |||
| Test | INIR-ME100%, INIR-ME5% | INIR-CD5.0% |
|---|---|---|
| Stabilisation or Warm-up Time (EN) | 0%v.v 0.1%Vol in 45 seconds | 0%v.v 0.01%Vol in 45 seconds |
| Calibration Curve (EN) / Basic Error (AQ) | 0 to 100% of full range -> 0.06%v.v or 6% of Reading | 0 to 5%v.v -> 0.06%v.v or 6% of Reading |
| Short Term Stability (EN) of Displayed Value (AQ) | 0%v.v = 0.005%v.v; 5%v.v = 0.1%v.v; 100%v.v = 1%v.v*3 | 0%v.v = 0.002%v.v; 5%v.v = 0.05%v.v |
| Minimum Resolution (AQ) | 0 to 5%v.v -> 0.002%v.v; 5 to 100%v.v -> 0.1%v.v*3 | 0 to 2%v.v -> 0.004%v.v; 2 to 5%v.v -> 0.01%v.v |
| Long Term Stability (EN) / Working Stability (AQ) | 0%v/v = 0.01%v.v / Month; 5%v/v = 0.1%v.v / Month; 100%v/v = 1.5%v.v / Month*3 | 0%v/v = 0.05%v.v / Month; 2%v/v = 0.05%v.v / Month; 5%v/v = 0.1%v.v / Month |
| Temperature Error (Compensation) (-40C to +75C, rel. to 20C) | 0%v.v to 5%v.v = 0.05%v/v; 5%v.v to 20%v.v = 0.2%v.v*3; 20%v.v to 100%v.v = 2%v.v*3 | 0%v/v to 2%v.v = 0.01%v.v; 2%v/v to 4%v.v = 0.02%v.v; 4%v.v to 5%v.v = 0.05%v.v |
| Humidity Error (10%RH to 90%RH, rel. to 45%RH) | 0%v.v = 0.05%v.v; 5%v.v = 0.1%v.v; 100%v.v = 1.5%v.v*3 | 0%v/v = 0.01%v.v; 5%v/v = 0.05%v.v |
| Response Time*2 (without dust filter) | Typ. T90 18 sec, Max T90 30 sec | Typ. T90 18 sec, Max T90 30 sec |
| Power Supply Variations (5% of Nominal Voltage) | Performance not affected if DC regulated voltage is provided. | |
| Power Supply Rejection Ratio (PSRR) (5% of Nominal Voltage) | 1 MHz -> 50 dB, 100 kHz -> 68 dB, 10 kHz -> 88 dB | |
| Temperature Cycling/Ramping Drift (Max at 1.3C/min.) | 0%v/v = 0.05%v.v; 5%v/v = 0.2%v.v; 100%v/v = 3%v.v*3 | 0%v/v = 0.05%v.v; 2%v/v = 0.1%v.v; 5%v/v = 0.25%v.v |
| Thermal Shock Drift | 0%v/v = 0.05%v.v (max) | 0%v/v = 0.05%v.v (max) |
| Uncertainty Error of Calibration | 0.15% | |
| Error of the Actual Reading | 0.15% | |
|
|
gas detection sensor Amphenol INIR-ME5% offering high resolution and automatic range switching capabilities Images |