| Sign In | Join Free | My infospaceinc.com |
|
Operating Temperature : -40℃~+55℃
Description : Gas Sensor RoHS
Mfr. Part # : VQ548ZD-S
Model Number : VQ548ZD-S
| Model | Operating Voltage (V d.c) | Sensor Current (mA) | Minimum Sensitivity (mV/%Vol) | Offset (mV) | Routine Temperature Tested | Routine Burn-In and Drift Test | Outline |
|---|---|---|---|---|---|---|---|
| VQ546M | 4.25 0.1 | 50 60 | - (1% Methane) | 15 | No | No | A |
| VQ546MR | 4.25 0.1 | 50 60 | +4.0 (1% Methane) | 15 | No | No | A |
| VQ547TS | 3.0 0.1 | 40 50 | 21 (1.5% Ammonia) | 30 | Some | No | A |
| VQ548ZD | 3.0 0.1 | 67 80 | 20 (1% Methane) | 20 | No | No | B |
| VQ548ZD/W | 3.0 0.1 | 67 80 | 20 (1% Methane) | 20 | Yes | No | B |
| VQ548ZD-S | 3.0 0.1 | 67 80 | 20 (1% Methane) | 20 | No | Yes | B |
| VQ549ZD | 4.25 0.1 | 50 60 | 30 (1% Methane) | 20 | No | No | B |
| VQ549ZD/W | 4.25 0.1 | 50 60 | 30 (1% Methane) | 20 | Yes | No | B |
| Mechanical Dimensions: See outline, page 3 | |||||||
| Weight: 22g | |||||||
| Environmental Temperature range for operation and storage: 40 to +55 C | |||||||
| Humidity range for operation and storage: 0 to 80% (non-condensing) | |||||||
| Supply Voltage: 3.00 V to 4.25 V (Depending upon type) | |||||||
| Supply Power: 135 mW to 230 mW (Depending upon type) | |||||||
| Operating Temperature Range: -40C and +55C | |||||||
| Maximum Gas Concentrations: VQ546M, VQ546MR: 100%v/v; VQ547TS, VQ548, VQ549: 100%LEL | |||||||
| Warranty Period: 12 months | |||||||
| Product Marking: ATEX: II 2G Ex db IIC Gb I M2 Ex db I Mb; IECEx: Ex db IIC Gb Ex db I Mb Ta -40C to +55C, Pi: 2.5 W | |||||||
| Hazardous Area Installation Note: Maximum output (Po) not greater than 2.5 W for intrinsically safe supply. Maximum temperature rise on external surface does not exceed 64 C. | |||||||
|
|
Explosion proof miniature gas sensor head Amphenol VQ548ZD-S optimized for combustible gas detection Images |