| Sign In | Join Free | My infospaceinc.com |
|
Operating Temperature : -
Description : Gas Sensor RoHS
Mfr. Part # : VQ25B
Model Number : VQ25B
| Specification | Value | Notes |
|---|---|---|
| Element Type | Matched Pair | Used for combustible gas detection in air. Not generally suitable for methane. |
| Bridge Supply Voltage | 2.0 + 0.1 V | Continuous operation. |
| Bridge Power Consumption | 0.75 W max | |
| Minimum Sensitivity | 25 mV/1% n-butane | With recommended bridge circuit. |
| Linearity | Linear up to 1.5% n-butane | |
| Response Time | 3 seconds | To register 0.5% in a 1% concentration. Dependent on mounting type. |
| Trimming Resistor (R) | 39 to 120 | Supplied with elements, connected across compensator. |
| Outline Dimensions (Millimetres) | A: 11.05 0.25, B: 6.10 0.25, C: 3.56 0.13, D: 63.50 min, E: 1.02, F: 7.37 0.51, G: 8.20 max, H: 9.53, J: 1.52 | Nominal dimensions without limits. No bends in length J. |
| Mounting Arrangement | See page 3 | Can be under direct flow or diffusion conditions. |
| Recommended Mounting Dimensions (Millimetres) | AA: 19.05 max, AB: 9.53 0.13, AC: 8.33 0.13, AD: 8.20 min, AE: 19.05 max, AF: 9.53 0.13, AG: 8.20 min | |
| Filter Paper & Gauze | 60 mesh stainless steel gauze | Used in mounting arrangements. |
|
|
Combustible Gas Detector Elements Featuring Amphenol VQ25B for Detection in Industrial Applications Images |