| Sign In | Join Free | My infospaceinc.com |
|
Description : MiNiFLP-3 Switches (Solid State) RoHS
Mfr. Part # : MRMS543E
Model Number : MRMS543E
Package : MiNiFLP-3
This document specifies a magnetic sensor that operates by detecting magnetic fields to perform ON/OFF functions. It is designed for applications where the function is not directly related to the protection of human life and property.
| Parameter | Symbol | Conditions | Min. | Typ. | Max. | Unit |
|---|---|---|---|---|---|---|
| Supply voltage | VCC | 1.6 | 1.8 | 3.6 | V | |
| Absolute max. supply voltage | - | - | 6.0 | V | ||
| Current consumption (No Load Resistance, Average current) | ICC | - | 16 | 40 | A | |
| Operating magnetic field | Hon | No Load Resistance | 1.4 | - | 3.1 | mT |
| Operating magnetic field | Hoff | No Load Resistance | 0.5 | - | - | mT |
| Frequency response | No Load Resistance | 0.5 | 1.0 | - | kHz | |
| Output Voltage (High) | VOH | No Load Resistance | 1.6 | - | - | V |
| Output Voltage (Low) | VOL | No Load Resistance | - | - | 0.2 | V |
| Operating temp. range | TA | -40 | - | +105 | ||
| Storage temp. range | -40 | - | +125 |
Applications listed in "Limitation of applications" in this document.
: Control code (One alphabetic character)
: Manufactured year (Last digit of the year)
: Manufactured month (1-9: 1-9, 10-12: X, Y, Z)
Note: The land pattern is an example. Please evaluate your soldering paste and reflow conditions with the product mounted on your equipment.
Note: Ensure the sensing direction of the sensor aligns with the applied magnetic field direction.
(Refer to image in original document - not representable in text)
VOUT level changes based on the applied magnetic field intensity (Positive logic). ON/OFF switching occurs depending on the magnetic field strength.
Note 1: The magnetic sensor has an internal intermittent switch circuit. The timing of VOUT change is within the ICC on period. Note 2: Consider the speed of magnetic field change relative to the intermittent operation speed in your design.
Form of packing: Tape & reel (180, 3000pcs per reel).
Maximum reflow condition: Absolute maximum package peak temperature is 260 for less than 10 seconds. Temperatures in the table/figure are package surface temperatures. Preheating conditions must be within the specified range.
(Refer to detailed table in original document for specific tests and criteria)
|
|