working temperature : -40℃~+125℃
Current Range : ±1kA
Voltage - Supply : 4.5V~5.5V
Sensitivity : 2mV/A
Description : ±1kA 2mV/A Current Sensors RoHS
Mfr. Part # : CSHV1000A-001
Model Number : CSHV1000A-001
The CSHV Series are open-loop Hall-effect current sensors from Honeywell, offering a robust combination of performance and reliability for current sensing applications. These non-intrusive, electrically isolated sensors are designed for primary current measurement ranges of 100 A to 1500 A dc. AEC-Q100 qualified, they provide accurate and stable measurements essential for motor control, battery management, and fault detection in electrified vehicles and industrial equipment. Customizable solutions and global technical support are available.
| Catalog Listing | Measure Range (A) | Sensitivity (mV/A at VS = 5 V) | Offset (mV at VS = 5 V) | Accuracy (% at VS = 5 V) 25C | Accuracy (% at VS = 5 V) -40C to 85C | Accuracy (% at VS = 5 V) -40C to 125C |
| CSHV100A-001 | ±100 | 20 | ±7 mV | ±1 % | ±2 % | |
| CSHV200A-001 | ±200 | 10 | ±7 mV | ±1 % | ±2 % | |
| CSHV300A-001 | ±300 | 6.667 | ±7 mV | ±1 % | ±2 % | |
| CSHV400A-001 | ±400 | 5 | ±7 mV | ±1 % | ±2 % | |
| CSHV500A-001 | ±500 | 4 | ±7 mV | ±1 % | ±2 % | |
| CSHV600A-001 | ±600 | 3.333 | ±7 mV | ±1 % | ±2 % | |
| CSHV700A-001 | ±700 | 2.857 | ±7 mV | ±1 % | ±2 % | |
| CSHV800A-001 | ±800 | 2.5 | ±7 mV | ±1 % | ±2 % | |
| CSHV900A-001 | ±900 | 2.222 | ±7 mV | ±1 % | ±2 % | |
| CSHV1000A-001 | ±1000 | 2 | ±7 mV | ±1 % | ±2 % | |
| CSHV1100A-001 | ±1100 | 1.818 | ±7 mV | ±1 % | ±2 % | |
| CSHV1200A-001 | ±1200 | 1.667 | ±7 mV | ±1 % | ±2 % | |
| CSHV1500A-001 | ±1500 | 1.333 | ±7 mV | ±2 % | ±3 % |
| Characteristic | Symbol | Unit | Parameter | Condition | Min. | Typ. | Max. |
| Supply voltage max. | VS max. | V | 10 | ||||
| Reverse supply voltage max. | VR max. | V | -0.3 | ||||
| Output voltage max. | VOUT max. | V | -0.3 | 10 | |||
| Output current max. | IOUT max. | mA | -10 | 10 | |||
| Ambient storage temperature | °C | -40 | 125 | ||||
| Electrostatic discharge voltage | VESD | kV | 8 | ||||
| RMS voltage for AC isolation test | VDWV | kV | 50 Hz, 1 min | 2.5 | |||
| Creepage distance | dCp | mm | 4.9 | ||||
| Clearance | dCl | mm | 4.9 | ||||
| Comparative tracking index | CTI | PLC3 | |||||
| Primary current, nominal DC | IPN | A | -IPN | IPN | |||
| Supply voltage | VS | V | 4.5 | 5 | 5.5 | ||
| Output voltage (at IP = 0) | VOS | V | 2.500 | ||||
| Electrical offset voltage | VOS, ELECT | mV | TA = 25°C, VS = 5 V | ±3 | |||
| Magnetic offset voltage | VOS, MAG | mV | TA = 25°C, VS = 5 V | ±2 | |||
| Current consumption | ISUPPLY | mA | TA = 25°C, VS = 5 V | 13 | |||
| Load resistance | RL | Ohm | 10k | ||||
| Output impedance | Rout | Ohm | 1 | ||||
| Ratiometric error | εr | % | TA = 25°C | ±0.5 | |||
| Sensitivity error: ±100 A to ±1200 A | εg | % | TA = 25°C, VS = 5 V | ±0.6 | |||
| Sensitivity error: ±1500 A | εg | % | TA = 25°C, VS = 5 V | ±0.8 | |||
| Linearity error | εL | % | of full scale output | -1 | 1 | ||
| Ambient operating temperature | °C | -40 | 125 | ||||
| Average temperature coefficient VOS, ELECT | mV/°C | ±0.04 | |||||
| Average temperature coefficient of G | %/°C | ±0.02 | |||||
| Step response time (10 % to 90 %) | tr | µs | 2 | 6 | |||
| Frequency bandwidth | BW | kHz | -3 dB | 45 | |||
| Output RMS noise (RMS) | mV | 2 |
|
|
current sensing Honeywell CSHV1000A-001 Hall effect sensor for electrified vehicle fault detection Images |