Description : Current Sensors RoHS
Mfr. Part # : HS1V 500 H05
Model Number : HS1V 500 H05
The HS1V H05 SERIES is an open-loop Hall Effect current sensor designed for the electronic measurement of DC, AC, and pulsed currents. It provides galvanic separation between the primary and secondary circuits, featuring an output voltage proportional to the supply voltage. Its compact size, UL 94-V0 rated insulating plastic case, and no insertion loss make it suitable for various demanding applications.
| Model | Primary Nominal RMS Current (IPN) | Primary Current Measuring Range (IPM) | Supply Voltage (VC) | Current Consumption (IC) | Load Resistance (RL) | Output Voltage (VOUT @ IPN) | Electrical Offset Voltage (VOE) | Temperature Coefficient of VOE (TCVOE) | Theoretical Sensitivity (Gth) | Sensitivity Error (G) | Temperature Coefficient of Sensitivity (TCG) | Linearity Error (L) | Hysteresis Offset Voltage (VOM) | Accuracy @ IPN (X) | Response Time (tr) | Frequency Bandwidth (-3dB) (BW) |
| HS1V 50 H05 | 50A | -150 to 150A | 12 to 15V | 32mA | 10k | 4.000V | -20 to 20mV | -0.8 to 0.8mV/K | 80.00mV/A | -0.5 to 0.5% | -0.1 to 0.1%/K | -0.5 to 0.5% of IPN | -10 to 10mV | -1 to 1% of IPN | 3s | 50kHz |
| HS1V 100 H05 | 100A | -300 to 300A | 12 to 15V | 32mA | 10k | 4.000V | -20 to 20mV | -0.8 to 0.8mV/K | 40.00mV/A | -0.5 to 0.5% | -0.1 to 0.1%/K | -0.5 to 0.5% of IPN | -10 to 10mV | -1 to 1% of IPN | 3s | 50kHz |
| HS1V 200 H05 | 200A | -600 to 600A | 12 to 15V | 32mA | 10k | 4.000V | -20 to 20mV | -0.8 to 0.8mV/K | 20.00mV/A | -0.5 to 0.5% | -0.1 to 0.1%/K | -0.5 to 0.5% of IPN | -10 to 10mV | -1 to 1% of IPN | 3s | 50kHz |
| HS1V 300 H05 | 300A | -900 to 900A | 12 to 15V | 32mA | 10k | 4.000V | -20 to 20mV | -0.8 to 0.8mV/K | 13.33mV/A | -0.5 to 0.5% | -0.1 to 0.1%/K | -0.5 to 0.5% of IPN | -10 to 10mV | -1 to 1% of IPN | 3s | 50kHz |
| HS1V 400 H05 | 400A | -900 to 900A | 12 to 15V | 32mA | 10k | 4.000V | -20 to 20mV | -0.8 to 0.8mV/K | 10.00mV/A | -0.5 to 0.5% | -0.1 to 0.1%/K | -0.5 to 0.5% of IPN | -10 to 10mV | -1 to 1% of IPN | 3s | 50kHz |
| HS1V 500 H05 | 500A | -900 to 900A | 12 to 15V | 32mA | 10k | 4.000V | -20 to 20mV | -0.8 to 0.8mV/K | 8.00mV/A | -0.5 to 0.5% | -0.1 to 0.1%/K | -0.5 to 0.5% of IPN | -10 to 10mV | -1 to 1% of IPN | 3s | 50kHz |
| HS1V 600 H05 | 600A | -900 to 900A | 12 to 15V | 32mA | 10k | 4.000V | -20 to 20mV | -0.8 to 0.8mV/K | 6.67mV/A | -0.5 to 0.5% | -0.1 to 0.1%/K | -0.5 to 0.5% of IPN | -10 to 10mV | -1 to 1% of IPN | 3s | 50kHz |
| Parameter | Symbol | Unit | Value |
| Supply voltage | VC | V | 18V |
| Primary conductor temperature | TB | 100 |
| Parameter | Symbol | Unit | Min | Typ | Max | Comment |
| Ambient operating temperature | TA | -40 | 105 | |||
| Ambient storage temperature | TS | -40 | 105 | |||
| Mass | m | g | 5 |
| Parameter | Symbol | Unit | Value | Comment |
| Rms voltage for AC insulation test @ 50Hz,1min | Vd | kV | 3.6 | According to IEC 60664-1 |
| Impulse withstand voltage 1.2/50s | VW | kV | 6.6 | According to IEC 60664-1 |
| Clearance (pri.- sec.) | dCI | mm | 6.3 | |
| Creepage distance (pri.- sec.) | dCp | mm | 7.3 | |
| Plastic case | - | - | UL94-V0 | |
| Comparative tracking index | CTI | PLC | 3 |
|
|