| Sign In | Join Free | My infospaceinc.com |
|
Description : Current Sensors RoHS
Mfr. Part # : HS1V 600 H03
Model Number : HS1V 600 H03
The HS1V H03 Series is an open-loop Hall effect current sensor designed for the electronic measurement of DC, AC, and pulsed currents. It provides galvanic separation between the primary and secondary circuits, ensuring safety and reliability. Key advantages include its small size, no insertion losses, and an output voltage proportional to the supply voltage. This sensor is suitable for a wide range of applications in power electronics and industrial automation.
| Model | Primary Nominal RMS Current (IPN) | Primary Current Measuring Range (IPM) | Supply Voltage (VC) | Current Consumption (IC) | Theoretical Sensitivity (Gth) | Accuracy @ IPN | Response Time (tr) | Frequency Bandwidth (-3dB) (BW) |
| HS1V 50 H03 | 50 A | -150 to 150 A | 12 to 15 V | 32 mA (@+15V), 0.6 mA (@-15V) | 80.00 mV/A | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 100 H03 | 100 A | -300 to 300 A | 12 to 15 V | 32 mA (@+15V), 0.6 mA (@-15V) | 40.00 mV/A | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 200 H03 | 200 A | -600 to 600 A | 12 to 15 V | 32 mA (@+15V), 0.6 mA (@-15V) | 20.00 mV/A | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 300 H03 | 300 A | -900 to 900 A | 12 to 15 V | 32 mA (@+15V), 0.6 mA (@-15V) | 13.33 mV/A | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 400 H03 | 400 A | -900 to 900 A | 12 to 15 V | 32 mA (@+15V), 0.6 mA (@-15V) | 10.00 mV/A | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 500 H03 | 500 A | -900 to 900 A | 12 to 15 V | 32 mA (@+15V), 0.6 mA (@-15V) | 8.00 mV/A | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 600 H03 | 600 A | -900 to 900 A | 12 to 15 V | 32 mA (@+15V), 0.6 mA (@-15V) | 6.67 mV/A | -1 to 1 % of IPN | 3 s | 50 kHz |
| Parameter | Symbol | Unit | Min | Typ | Max | Comment |
| Supply voltage | VC | V | 12 | 15 | 18 | Absolute maximum rating |
| Primary conductor temperature | TB | 100 | Absolute maximum rating | |||
| Ambient operating temperature | TA | -40 | 105 | |||
| Ambient storage temperature | TS | -40 | 105 | |||
| Mass | m | g | 57 | |||
| Rms voltage for AC insulation test @ 50Hz,1min | Vd | kV | 3.6 | |||
| Impulse withstand voltage 1.2/50s | VW | kV | 6.6 | |||
| Clearance (pri.- sec.) | dCI | mm | 6.3 | |||
| Creepage distance (pri.- sec.) | dCp | mm | 7.3 | |||
| Plastic case | UL94-V0 | |||||
| Comparative tracking index | CTI | PLC | 3 | |||
| Output voltage (Analog) @ IPN | VOUT | V | 4.000 | |||
| Electrical offset voltage | VOE | mV | -20 | 20 | ||
| Temperature coefficient of VOE | TCVOE | mV/K | -0.8 | 0.8 | @ -40~105 | |
| Sensitivity error | G | % | -0.5 | 0.5 | exclusive of VOE | |
| Temperature of G | TCG | %/K | -0.1 | 0.05 | 0.1 | @ -40~105 |
| Linearity error 0IPN | L | % of IPN | -0.5 | 0.5 | exclusive of VOE | |
| Hysteresis offset voltage @ IP=0 after 1IPN | VOM | mV | -10 | 4 | 10 | |
| Overall accuracy @ IPN | X | % of IPN | -1 | 1 | exclusive of VOE |
|
|
Open loop Hall effect current sensor CHIPSENSE HS1V 600 H03 for DC AC and pulsed current measurement Images |