| Sign In | Join Free | My infospaceinc.com |
|
Pressure range : ±2.49Kpa
Description : ±2.49Kpa SIP-4 Pressure Sensors, Transducers RoHS
Mfr. Part # : MLV-L10D-E1NS-N
Model Number : MLV-L10D-E1NS-N
Package : SIP-4
The All Sensors MLV Series Compensated Sensor leverages CoBeam2 Technology to deliver a high output signal at a low operating voltage. This design offers comparable output to traditional compensated millivolt sensors operating at higher voltages, leading to improved warm-up shift. The CoBeam2 Technology also enhances long-term stability by reducing package stress susceptibility and significantly improves position sensitivity compared to conventional single-die devices. These calibrated and compensated sensors provide accurate and stable output across a wide temperature range, making them suitable for non-corrosive, non-ionic working fluids like air and dry gases. An optional protective parylene coating is available for enhanced moisture and harsh media protection. The output is ratiometric to the supply voltage and designed for 5.0 VDC operation.
| Model | Device Operating Range | Proof Pressure | Burst Pressure | Nominal Span | Supply Voltage (Vs) Max | Compensated Temperature Range | Operating Temperature Range | Storage Temperature Range |
|---|---|---|---|---|---|---|---|---|
| MLV-L01D | 1 inH2O | 100 inH2O | 300 inH2O | 7 mV | 12 Vdc | 0C to 50C | -25C to 85C | -40C to 125C |
| MLV-L02D | 2 inH2O | 100 inH2O | 300 inH2O | 10 mV | ||||
| MLV-L05D | 5 inH2O | 200 inH2O | 300 inH2O | 15 mV | ||||
| MLV-L10D | 10 inH2O | 200 inH2O | 300 inH2O | 20 mV | ||||
| MLV-L20D | 20 inH2O | 200 inH2O | 500 inH2O | 20 mV | ||||
| MLV-L30D | 30 inH2O | 200 inH2O | 800 inH2O | 20 mV | ||||
| MLV-005D | 5 PSI | 10 PSI | 30 PSI | 25 mV | 12 Vdc | 0C to 50C | -25C to 85C | -40C to 125C |
| MLV-015D | 15 PSI | 60 PSI | 120 PSI | 37.5 mV | ||||
| MLV-015A | 0 - 15 PSIA | 60 PSI | 120 PSI | 37.5 mV | ||||
| MLV-030D | 30 PSI | 90 PSI | 150 PSI | 37.5 mV | ||||
| MLV-100D | 100 PSI | 200 PSI | 250 PSI | 41.67 mV | ||||
| MLV-150D | 150 PSI | 200 PSI | 250 PSI | 37.5 mV |
Note: All parameters are measured at 5.0 volt excitation and room temperature unless otherwise specified. Pressure measurements are with positive pressure applied to PORT B (the only port for single port configuration packages).
Environmental Specifications:
Maximum Ratings:
|
|
compensated low voltage pressure sensor Amphenol MLV-L10D-E1NS-N with enhanced position sensitivity Images |