| Sign In | Join Free | My infospaceinc.com |
|
Standby Current : 10mA
working temperature : -40℃~+85℃
Current Range : 130A
Voltage - Supply : -12V~15V
Band Width : 150kHz
Response Time (tr) : 300ns
Bidirectional Current Detection : Support
Description : 130A Through Hole Current Sensors RoHS
Mfr. Part # : LA130-P
Model Number : LA130-P
Package : Through Hole
The LEM LA 130-P is a closed-loop Hall effect current transducer designed for electronic measurement of DC, AC, and pulsed currents with galvanic separation between primary and secondary circuits. It offers excellent accuracy, very good linearity, low temperature drift, and optimized response time, making it suitable for various industrial applications such as AC and DC motor drives, UPS, SMPS, and welding power supplies. The transducer features an insulating plastic case recognized according to UL 94-V0 and provides high immunity to external interference with current overload capability.
| Parameter | Symbol | Unit | Value | Notes |
| Primary nominal rms current | IPN | A | 130 | |
| Primary current, measuring range | IPM | A | 0 .. 200 | |
| Secondary nominal rms current | ISN | mA | 130 | |
| Conversion ratio | KN | : | 1 : 1000 | |
| Supply voltage | UC | V DC | 12 .. 15 | (5 %) |
| Current consumption | IC | mA | 10 (@ 15 V) + Is | |
| Accuracy @ IPN, TA = 25 C | X | % | <0.5 | |
| Linearity error | L | % | <0.1 | Typ |
| Electrical offset current @ IP = 0, TA = 25 C | IOE | mA | 0.20 | |
| Magnetic offset current @ IP = 0 and specified RM, after an overload of 3 IPN | IOM | mA | 0.50 | |
| Temperature variation of IO (-40 C .. +85 C) | IOT | mA | 0.30 / 0.60 | Max |
| Reaction time | tra | ns | <300 | |
| Step response time (1) to 90 % of IPN | tr | ns | <500 | (1) With a di/dt of 100 A/s. |
| di/dt accurately followed | di/dt | A/s | >100 | |
| Frequency bandwidth (-1 dB) | BW | kHz | DC .. 150 | |
| Ambient operating temperature | TA | C | -40 .. +85 | |
| Ambient storage temperature | TS | C | -40 .. +90 | |
| Resistance of secondary winding @ TA = 25 C | RS | 211.5 | ||
| Mass | m | g | <25 | |
| Insulation coordination: Rms voltage for AC insulation test, 50 Hz/1 min | Ud | kV | 4.3 | |
| Impulse withstand voltage 1.2/50 s | W | kV | 8 | |
| Partial discharge extinction rms voltage @ 10 pC | Ue | kV | 1.3 | |
| Min creepage distance | dCp | mm | 8 | |
| Min clearance | dCI | mm | 8 | |
| Comparative tracking index (group I) | CTI | 600 | ||
| Primary potential involved | V | AC/DC | 600 | UL 508: Ratings |
| Max surrounding air temperature | TA | C | 85 | UL 508: Ratings |
| Secondary supply voltage | UC | V DC | 12 .. 15 | UL 508: Ratings |
| Output signal | ISN | mA | 130 | UL 508: Ratings |
|
|