| Sign In | Join Free | My infospaceinc.com |
|
working temperature : -10℃~+80℃
Current Range : ±1.5kA
Voltage - Supply : ±15V
Band Width : 25kHz
Response Time (tr) : 5us
Bidirectional Current Detection : Support
Description : ±1.5kA Current Sensors RoHS
Mfr. Part # : hat500-s
Model Number : hat500-s
The LEM HAT 200..1500-S is a current transducer utilizing the Hall effect principle for the electronic measurement of DC, AC, and pulsed currents. It offers galvanic isolation between the primary (high power) and secondary (electronic) circuits, making it suitable for a wide range of industrial applications. Key advantages include easy installation, small size, and high immunity to external interference.
| Type | Primary Nominal Current (IPN) (A) | Primary Measuring Range (IPM) (A) | Supply Voltage (VC) ( 5 %) | Current Consumption (IC) | Isolation Resistance (@ 500 VDC) | Output Voltage (VOUT) (@ IPN, RL =10 k, TA = 25C) | Load Resistance (RL) | Accuracy (@ IPN, TA = 25C) | Linearity Error (L) (0 .. IPN) | Electrical Offset Voltage (VOE) (@ TA = 25C) | Hysteresis Offset Voltage (VOH) (@ IP = 0, after an excursion of 1 x IPN) | Temp. Coefficient of VOE (TCVOE) | Temp. Coefficient of VOUT (TCVOUT) (% of reading) | Response Time to 90% of IPN step (tr) | Frequency Bandwidth (BW) (- 3 dB) | Ambient Operating Temperature (TA) | Ambient Storage Temperature (TS) | Mass (m) | Isolation Voltage (Vd) Rms voltage for AC isolation test, 50 HZ, 1 min | Impulse Withstand Voltage (Vw) 1.2/50 s | Creepage Distance (dCp) | Clearance Distance (dCI) | Comparative Tracking Index (CTI) |
| HAT 200-S | 200 | 600 | 15 V | 15 mA | > 1000 M | 4 V | > 10 k | 1 % of IPN | 1 % of IPN | < 20 mV | < 10 mV | < 1 mV/K | < 0.1 %/K | < 5 s | DC .. 25 kHz | - 10 .. + 80 C | - 25 .. + 85 C | 300 g | 4.9 kV | > 9.0 kV | 9.9 mm | 9.9 mm | 275 |
| HAT 400-S | 400 | 1200 | 15 V | 15 mA | > 1000 M | 4 V | > 10 k | 1 % of IPN | 1 % of IPN | < 20 mV | < 10 mV | < 1 mV/K | < 0.1 %/K | < 5 s | DC .. 25 kHz | - 10 .. + 80 C | - 25 .. + 85 C | 300 g | 4.9 kV | > 9.0 kV | 9.9 mm | 9.9 mm | 275 |
| HAT 500-S | 500 | 1500 | 15 V | 15 mA | > 1000 M | 4 V | > 10 k | 1 % of IPN | 1 % of IPN | < 20 mV | < 10 mV | < 1 mV/K | < 0.1 %/K | < 5 s | DC .. 25 kHz | - 10 .. + 80 C | - 25 .. + 85 C | 300 g | 4.9 kV | > 9.0 kV | 9.9 mm | 9.9 mm | 275 |
| HAT 600-S | 600 | 1800 | 15 V | 15 mA | > 1000 M | 4 V | > 10 k | 1 % of IPN | 1 % of IPN | < 20 mV | < 10 mV | < 1 mV/K | < 0.1 %/K | < 5 s | DC .. 25 kHz | - 10 .. + 80 C | - 25 .. + 85 C | 300 g | 4.9 kV | > 9.0 kV | 9.9 mm | 9.9 mm | 275 |
| HAT 800-S | 800 | 2400 | 15 V | 15 mA | > 1000 M | 4 V | > 10 k | 1 % of IPN | 1 % of IPN | < 20 mV | < 10 mV | < 1 mV/K | < 0.1 %/K | < 5 s | DC .. 25 kHz | - 10 .. + 80 C | - 25 .. + 85 C | 300 g | 4.9 kV | > 9.0 kV | 9.9 mm | 9.9 mm | 275 |
| HAT 1000-S | 1000 | 2500 | 15 V | 15 mA | > 1000 M | 4 V | > 10 k | 1 % of IPN | 1 % of IPN | < 20 mV | < 10 mV | < 1 mV/K | < 0.1 %/K | < 5 s | DC .. 25 kHz | - 10 .. + 80 C | - 25 .. + 85 C | 300 g | 4.9 kV | > 9.0 kV | 9.9 mm | 9.9 mm | 275 |
| HAT 1200-S | 1200 | 2500 | 15 V | 15 mA | > 1000 M | 4 V | > 10 k | 1 % of IPN | 1 % of IPN | < 20 mV | < 10 mV | < 1 mV/K | < 0.1 %/K | < 5 s | DC .. 25 kHz | - 10 .. + 80 C | - 25 .. + 85 C | 300 g | 4.9 kV | > 9.0 kV | 9.9 mm | 9.9 mm | 275 |
| HAT 1500-S | 1500 | 2500 | 15 V | 15 mA | > 1000 M | 4 V | > 10 k | 1 % of IPN | 1 % of IPN | < 20 mV | < 10 mV | < 1 mV/K | < 0.1 %/K | < 5 s | DC .. 25 kHz | - 10 .. + 80 C | - 25 .. + 85 C | 300 g | 4.9 kV | > 9.0 kV | 9.9 mm | 9.9 mm | 275 |
|
|
Current measurement sensor LEM hat500-s with galvanic isolation and high immunity to external interference Images |