working temperature : -10℃~+80℃
Current Range : ±900A
Voltage - Supply : ±15V
Band Width : 50kHz
Bidirectional Current Detection : Support
Description : ±900A Through Hole Current Sensors RoHS
Mfr. Part # : HAS500-S
Model Number : HAS500-S
Package : Through Hole
The LEM HAS 50..600-S is a current transducer for the electronic measurement of DC, AC, and pulsed currents with galvanic separation between primary and secondary circuits. It features a Hall effect measuring principle and an insulating plastic case made of polycarbonate PBT. Key advantages include easy mounting, low power consumption, small size, a single design for wide current ratings, and high immunity to external interference. This transducer is designed for industrial applications such as AC variable speed drives, static converters for DC motor drives, battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), and power supplies for welding applications.
| Type | Primary nominal rms current IPN (A) | Primary current measuring range IPM (A) | Supply voltage (5 %) UC | Current consumption IC | Insulation resistance @ 500 V DC | Output voltage (Analog) @ IPN, RL = 10 k, TA = 25 C | Output internal resistance | Load resistance RL 2) | Accuracy @ IPN, TA = 25 C (excluding offset) | Linearity error 3) (0 .. IPN) | Electrical offset voltage, TA = 25 C VOE | Hysteresis offset voltage @ IP = 0, after an excursion of 1 IPN VOH | Temperature coefficient of VOE | Temperature coefficient of Vout (% of reading) | Step response time to 90 % of IPN | di/dt accurately followed | Frequency bandwidth (-3 dB) 4) | Ambient operating temperature | Ambient storage temperature | Mass | Ud Rms voltage for AC insulation test, 50 Hz/1 min | W Impulse withstand voltage 1.2/50 s | Min dCp Creepage distance | dCI Clearance | CTI Comparative tracking index (group IIIa) |
| HAS 50-S | 50 | 150 | 15 V | 15 mA | >1000 M | 4 V | approx 100 | >1 k | <1 % of IPN | <1 % of IPN | <20 mV | <20 mV | <2 mv> | <0.1 %/K | <3 s | >50 A/s | DC .. 50 kHz | -10 .. +80 C | -25 .. +80 C | approx 60 g | 3.6 kV | >6.6 kV | 7.08 mm | 6.23 mm | 275 |
| HAS 100-S | 100 | 300 | 15 V | 15 mA | >1000 M | 4 V | approx 100 | >1 k | <1 % of IPN | <1 % of IPN | <20 mV | <20 mV | <1 mv> | <0.1 %/K | <3 s | >50 A/s | DC .. 50 kHz | -10 .. +80 C | -25 .. +80 C | approx 60 g | 3.6 kV | >6.6 kV | 7.08 mm | 6.23 mm | 275 |
| HAS 200-S | 200 | 600 | 15 V | 15 mA | >1000 M | 4 V | approx 100 | >1 k | <1 % of IPN | <1 % of IPN | <20 mV | <20 mV | <1 mv> | <0.1 %/K | <3 s | >50 A/s | DC .. 50 kHz | -10 .. +80 C | -25 .. +80 C | approx 60 g | 3.6 kV | >6.6 kV | 7.08 mm | 6.23 mm | 275 |
| HAS 300-S | 300 | 900 | 15 V | 15 mA | >1000 M | 4 V | approx 100 | >1 k | <1 % of IPN | <1 % of IPN | <20 mV | <20 mV | <1 mv> | <0.1 %/K | <3 s | >50 A/s | DC .. 50 kHz | -10 .. +80 C | -25 .. +80 C | approx 60 g | 3.6 kV | >6.6 kV | 7.08 mm | 6.23 mm | 275 |
| HAS 400-S | 400 | 900 | 15 V | 15 mA | >1000 M | 4 V | approx 100 | >1 k | <1 % of IPN | <1 % of IPN | <20 mV | <20 mV | <1 mv> | <0.1 %/K | <3 s | >50 A/s | DC .. 50 kHz | -10 .. +80 C | -25 .. +80 C | approx 60 g | 3.6 kV | >6.6 kV | 7.08 mm | 6.23 mm | 275 |
| HAS 500-S | 500 | 900 | 15 V | 15 mA | >1000 M | 4 V | approx 100 | >1 k | <1 % of IPN | <1 % of IPN | <20 mV | <20 mV | <1 mv> | <0.1 %/K | <3 s | >50 A/s | DC .. 50 kHz | -10 .. +80 C | -25 .. +80 C | approx 60 g | 3.6 kV | >6.6 kV | 7.08 mm | 6.23 mm | 275 |
| HAS 600-S | 600 | 900 | 15 V | 15 mA | >1000 M | 4 V | approx 100 | >1 k | <1 % of IPN | <1 % of IPN | <20 mV | <20 mV | <1 mv> | <0.1 %/K | <3 s | >50 A/s | DC .. 50 kHz | -10 .. +80 C | -25 .. +80 C | approx 60 g | 3.6 kV | >6.6 kV | 7.08 mm | 6.23 mm | 275 |
|
|