High accuracy isolated current sensor LEM LT208-S7 designed for DC AC and pulse current applications

working temperature : -10℃~+70℃

Current Range : ±300A

Voltage - Supply : -15V~-12V;12V~15V

Band Width : 100kHz

Bidirectional Current Detection : Support

Description : ±300A Current Sensors RoHS

Mfr. Part # : LT208-S7

Model Number : LT208-S7

Contact Now

Product Overview

The LEM LT 208-S7 is an isolated current sensor designed for measuring DC, AC, and pulse currents. It offers excellent accuracy, linearity, low temperature drift, and fast response times, making it suitable for a wide range of industrial applications including variable speed drives, servo motors, and power supplies.

Product Attributes

  • Brand: LEM
  • Model: LT 208-S7
  • Certifications: EN 50178, UL 94-V0 (insulation housing)
  • Origin: China (implied by Shanghai Jiaren mention)

Technical Specifications

ParameterValueUnitNotes
Primary Rated RMS Current (IPN)200A
Primary Current Measuring Range (IPM)0 .. 300A
Secondary Rated RMS Current (ISN)100mA
Conversion Ratio (KN)1 : 2000
Supply Voltage (VC) 12 .. 15V( 5 %)
Current Consumption (IC)28 (@ 12V) + ISmA
Total Accuracy @ IPN, TA = 25C (XG) 0.5%
Linearity (L)< 0.1%Typ
Zero Offset Voltage @ IP = 0, TA = 25C (IO) 0.20mA
Magnetic Offset Current (IOM) 0.20mA@ IP = 0, overload through 3 x IPN
Temperature Drift of IO (IOT) 0.20 .. 0.64mA(- 10C .. + 70C)
Response Time to 10% of IPN (tra)< 500ns
Response Time to 90% of IPN (tr)< 1s2)
di/dt Following Accuracy> 100A/s
Bandwidth (- 3 dB) (BW)DC .. 100kHz
Ambient Operating Temperature (TA)- 10 .. + 70C
Ambient Storage Temperature (TS)- 25 .. + 80C
Secondary Coil Resistance @ TA = 70C (RS)21
Mass (m)79g
AC Isolation Test Voltage (Vd)3.52kV50 Hz, 1 min, primary-secondary
Impulse Withstand Voltage (Vw)6.5kV1.2/50 s
Creepage Distance (dCp)10mm2)
Clearance Distance (dCI)6mm2)
Comparative Tracking Index (CTI)275(group IIIa)
Load Voltage CategoryOV 3According to EN 50178
Pollution DegreePD2According to EN 50178

1912111437_LEM-LT208-S7_C454772.pdf


Quality High accuracy isolated current sensor LEM LT208-S7 designed for DC AC and pulse current applications for sale

High accuracy isolated current sensor LEM LT208-S7 designed for DC AC and pulse current applications Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Changsha Purple Horn E-Commerce Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)