| Sign In | Join Free | My infospaceinc.com |
|
Description : Accelerometers RoHS
Mfr. Part # : BW20-20
Model Number : BW20-20
The D-44 BW Series Area Sensor is a high-performance through-beam type sensor designed for long-distance detection up to 7 meters. It offers a wide sensing height range and minimizes unsensing areas with its 20mm optical axis pitch. Featuring high-brightness LEDs for easy recognition from various angles and distances, this sensor includes essential functions like self-diagnosis, mutual interference prevention, and external diagnosis. Its robust IP65 protection structure makes it suitable for demanding industrial environments.
| Model | Sensing Method | Sensing Distance | Min. Sensing Target | Optical Axis Pitch | Number of Optical Axis | Sensing Height | Response Time | Power Supply | Current Consumption | Operation Mode | Control Output | Protection Circuit | Insulation Resistance | Synchronization Type | Self-Diagnosis | Interference Protection | Noise Immunity | Dielectric Strength | Vibration | Shock | Ambient Illumination | Ambient Temperature | Ambient Humidity | Cable | Weight (Unit Only) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BW20-(P) | Through-beam type | 0.1 to 7m | Opaque material of min. 30mm | 20mm | 8 to 48 | 140 to 940mm | Max. 10ms | 12-24VDC 10% (ripple P-P: max. 10%) | Emitter: max. 120mA, Receiver: max. 120mA | Light ON fixed | NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC | Reverse polarity protection circuit, output short over current protection circuit | Over 20M (at 500VDC megger) | Timing method by synchronous line | Emitter/Receiver monitoring, direct light monitoring, over current monitoring | Interference protection by master/slave function | 240V the square wave noise (pulse width 1) by the noise simulator | 1,000VAC 50/60Hz for 1 min | 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | 500m/s (approx. 50G) in each X, Y, Z direction for 3 times | Max. 100,000lx (receiver illumination) | -10 to 55, storage: -20 to 60 | 35 to 85%RH, storage: 35 to 85%RH | 5mm, 4-wire, 300mm, M12 connector | Approx. 1.4kg |
| BW40-(P) | Through-beam type | 0.1 to 7m | Opaque material of min. 50mm | 40mm | 4 to 24 | 120 to 920mm | Max. 10ms | 12-24VDC 10% (ripple P-P: max. 10%) | Emitter: max. 120mA, Receiver: max. 120mA | Light ON fixed | NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC | Reverse polarity protection circuit, output short over current protection circuit | Over 20M (at 500VDC megger) | Timing method by synchronous line | Emitter/Receiver monitoring, direct light monitoring, over current monitoring | Interference protection by master/slave function | 240V the square wave noise (pulse width 1) by the noise simulator | 1,000VAC 50/60Hz for 1 min | 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | 500m/s (approx. 50G) in each X, Y, Z direction for 3 times | Max. 100,000lx (receiver illumination) | -10 to 55, storage: -20 to 60 | 35 to 85%RH, storage: 35 to 85%RH | 5mm, 4-wire, 300mm, M12 connector | Approx. 1.4kg |
| Item | Optical axis pitch | Number of optical axis | Control output | Model Example |
|---|---|---|---|---|
| No mark | 20mm | 04 to 48 | NPN open collector output | BW20-08(P) |
| P | 40mm | 4 to 48 | PNP open collector output |
Example: BW20-08P
(Diagrams for Emitter, Receiver, Bracket A, Bracket B are present in the source but cannot be rendered as HTML tables without specific data points. The following table provides key dimensional data derived from the diagrams.)
| Model | L (mm) | A (mm) | B (mm) | Optical Axis Pitch (mm) |
|---|---|---|---|---|
| BW20-08(P) | 160 | 20 | 40 | 20 |
| BW40-04(P) | 160 | 40 | 40 | 40 |
| BW20-12(P) | 240 | 20 | 40 | 20 |
| BW40-06(P) | 240 | 40 | 40 | 40 |
| BW20-16(P) | 320 | 20 | 40 | 20 |
| BW40-08(P) | 320 | 40 | 40 | 40 |
| BW20-20(P) | 400 | 20 | 40 | 20 |
| BW40-10(P) | 400 | 40 | 40 | 40 |
| BW20-24(P) | 480 | 20 | 40 | 20 |
| BW40-12(P) | 480 | 40 | 40 | 40 |
| BW20-28(P) | 560 | 20 | 40 | 20 |
| BW40-14(P) | 560 | 40 | 40 | 40 |
| BW20-32(P) | 640 | 20 | 40 | 20 |
| BW40-16(P) | 640 | 40 | 40 | 40 |
| BW20-36(P) | 720 | 20 | 40 | 20 |
| BW40-18(P) | 720 | 40 | 40 | 40 |
| BW20-40(P) | 800 | 20 | 40 | 20 |
| BW40-20(P) | 800 | 40 | 40 | 40 |
| BW20-44(P) | 880 | 20 | 40 | 20 |
| BW40-22(P) | 880 | 40 | 40 | 40 |
| BW20-48(P) | 960 | 20 | 40 | 20 |
| BW40-24(P) | 960 | 40 | 40 | 40 |
(Details on Input/Output Circuits, Operation Indicator, and Connections are provided in the source text but are best represented visually or with specific diagrams not reproducible here. The following table summarizes connection points.)
| Pin No. | Cable Color (Emitter/Receiver) | Emitter Function | Receiver Function |
|---|---|---|---|
| 1 | Brown | 12-24VDC | 12-24VDC |
| 2 | White | SYNC | SYNC |
| 3 | Blue | 0V | 0V |
| 4 | Black | TEST (M/S) | OUT |
Connecting Cables: Sold separately (e.g., CID4-3T, CID4-5T for Emitter; CID4-3R, CID4-5R for Receiver).
| Cause | Troubleshooting |
|---|---|
| Not operating | Supply the rated power. Check wiring for incorrect connection or disconnection. Use within the rated sensing distance. |
| Not operating sometimes | Remove dirt from the sensor cover. Check connector connections. |
| Control output is OFF even though there is no target object | Use within the rated sensing distance. Remove any obstacle blocking the light path. Move away from strong electric wave or noise generators. |
| LED displays for break of light emitting element | Break of light emitting element. |
| LED displays for failure of emitter | Break of light emitting circuit. |
| LED displays for failure of receiver | Break of light receiving element. |
| LED displays for synchronous line | Synchronous line incorrect connection or disconnection. Break of synchronous circuit of emitter or receiver. |
| LED displays for control output over current | Control output line is shorted. Overload. Check rated load capacity. |
| LED displays for emitter malfunction | Emitter malfunction. Treat after checking the emitter display LED. |
|
|